IntroductionVariTrane variable-air-volume (VAV) units lead the industry in quality and reliability and aredesigned to meet the specific needs of today’s applications. This generation of VariTrane unitsbuilds upon the history of quality and reliability and expands the products into the most completeVAV offering in the industry.Single-duct units provide an economical energy-savings system solution. This is the mostcommon type of VAV unit.Dual-duct units have two air valves. One heating valve and one cooling air valve modulatesimultaneously to provide occupant comfort. This option is also used with system concepts whichuse one valve for maintaining and monitoring 100% ventilation air.VCCFVCEFVCWFCopyrightThis document and the information in it are the property of Trane, and may not be used orreproduced in whole or in part without written permission. Trane reserves the right to revise thispublication at any time, and to make changes to its content without obligation to notify any personof such revision or change.TrademarksAll trademarks referenced in this document are the trademarks of their respective owners.Revision HistoryVAV-PRC011M-EN (033 Mar 2015)Updated for Air-Fi wireless project. 2015 Trane All rights reservedVAV-PRC011M-EN

Table of ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Indoor Air Quality (IAQ) Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Tracer Building Automation System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Trane VAV Systems - Proven Performance . . . . . . . . . . . . . . . . . . . . . . . . . 11Indoor Air Quality Management During Construction . . . . . . . . . . . . . . . . . 11Agency Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12American Society of Heating, Refrigerating and Air-conditioning Engineers(ASHRAE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Air Conditioning and Refrigeration Institute (AHRI) . . . . . . . . . . . . . . . . . . . 12Underwriter’s Laboratory (UL) 1995 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12National Fire Protection Association . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Model Number Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Single-Duct VAV Terminal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Model Number Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65Dual-Duct VAV Terminal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76DDC Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Tracer UC400 and UC210 Programmable BACnet Controllers . . . . . . . . . . 79Trane LonMark DDC VAV Controller (VV550) . . . . . . . . . . . . . . . . . . . . . . 88Direct Digital Controller—Unit Control Module (UCM4) . . . . . . . . . . . . . . . 97Air-Fi Wireless System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101Wireless Receiver/Wireless Zone Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . 103DDC Zone Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104VAV-PRC011M-EN3

Table of ContentsCO2 Wall Sensor and Duct CO2 Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105DDC Zone Sensor with LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106Zone Occupancy Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107Factory or Field Mounted Auxiliary Temperature Sensor . . . . . . . . . . . . . 108Factory Mounted Discharge Air Temperature Sensing Matrix . . . . . . . . . 108Two-Position Water Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109Proportional Water Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110VAV Piping Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111Differential Pressure Transducer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113Trane Non-Spring Return Actuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114Trane Spring Return Actuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115VariTrane DDC Retrofit Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116Retrofit Kit Actuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116Static Pressure Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117Electric Heater Silicon-Controlled Rectifier (SCR) . . . . . . . . . . . . . . . . . . . 118Pneumatic Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1213011 Pneumatic Volume Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1213501 Pneumatic Volume Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122Pneumatic Damper Actuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123Reversing Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123Signal Limiter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125Controls Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134Direct Digital Controls (DDC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134Pneumatic Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136DDC Retrofit Kit (VRTO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136Retrofit Kit Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136Other Options Available . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137Application Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138VAV System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138Control Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142Flow Measurement and Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146Reheat Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Acoustics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1504VAV-PRC011M-EN

Table of ContentsDuct Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153Best Practices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154Unit Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155Additional VAV System and Product References . . . . . . . . . . . . . . . . . . . . 156VAV-PRC011M-EN5

Features and BenefitsConstructionUL-listed productsSafety and reliability are vital in commercial construction. All VariTrane units are listed inaccordance with UL -1995 as terminal units. This listing includes the VAV terminal with electricheaters. Additionally, all insulation materials pass UL 25/50 smoke and flame safety standards.AHRI Certified PerformanceAll VariTrane units are AHRI certified. AHRI 880 guarantees the pressure drop, flow performance,and acoustical performance provided is reliable and has been tested in accordance with industryaccepted standards. AHRI 885 uses AHRI 880 performance and applies accepted industry methodsto estimate expected “NC” sound levels within the occupied space.Casing DesignInterlocking Panels—VariTrane products are manufactured in Trane’s state-of-the-art facility in theU. S. The interlocking panels are designed using integral I-beam construction technology. Thisminimizes deformation and creates tremendous product rigidity. An additional benefit is a smoothunit exterior with few exposed screws—ideal for exposed ceiling applications. VariTrane units aredesigned for use in systems that operate up to 5" w.c. of inlet pressure.Metal Encapsulated Edges—All VariTrane units are completewith encapsulated edges to arrest cut fibers and preventinsulation erosion into the airstream. This is the standard ofcare in applications concerned with fiberglass erosion orprojects with either double-wall or externally wrapped ductwork.The Trane Air Valve—is at the heart of VariTrane terminalunits. This is where airflow is measured and controlled.Repeatability and ruggedness is vital. VariTrane products arethe most rugged and reliable available.18-gage Cylinder—limits deformation or damage during shipment and job site handling, andprovides even airflow distribution across the flow ring for unmatched airflow measurementaccuracy.Continuously Welded Seam — an automated weld process creates the highest quality continuousseam, which is “right” every time. The welded seam improves air valve rigidity and createsconsistent and repeatable airflow across the flow measurement device. The result is a truly roundcylinder, with no flat spots caused by lower quality crimping and riveting technologies.Flow Ring—The Trane flow ring is time tested to perform under themost demanding conditions. Additionally, Trane’s patented flow ringis recessed within the air valve cylinder to reduce the potential fordamage during job site handling and installation.6VAV-PRC011M-EN

Features and BenefitsExternal Shaft—This simple design provides controller flexibility and is designed to facilitateactuator field replacement.Position Indicator—The position indicator shows current air valve position to aid in systemcommissioning. Many times this can be seen from the floor without climbing a ladder.External Actuator—This feature increases serviceability, control system compatibility, and actuatorclutch access for simplified commissioning.Indoor Air Quality (IAQ) FeaturesThe oil embargo of the early 1970s created an energy crisis, which resulted in tighter buildings, andreduced ventilation rates. A fallout issue of tighter building construction was poor indoor airquality. This heightened IAQ awareness. IAQ issues have been featured in publications from thesmallest towns to the largest cities. System design should consider applicable ventilation and IAQstandards.(See your local Trane Sales Engineer or visit www.trane.com for additional information).Good indoor air quality results from units and systems which: Provide the required amount of ventilation air to each zone during all operating conditions Limit particulates from entering occupied spacesVariTrane units are designed with simplified access and a full line of insulation options including:Matte-faced—Typical industry standard with reduced first cost.Closed-cell—This insulation has an R-value and performance equivalent to matte-faced insulation.The main difference is the reduction of water vapor transmission. Closed-cell is designed for usein installations with a high chance of water formation. (It has been used to coat the exterior of chillerevaporator barrels for many years.)Foil-faced—A fiberglass insulation with a thin aluminum coating on the air stream side to preventfibers from becoming airborne. The aluminum lining is acceptable for many applications, howeverit is not as rugged as double-wall.Double-wall—Premium insulation often used in many health care applications with insulationlocked between metal lin